This 24kva Able unit is ideal for customers who have 2 x Agras spray drones. It will run 2 x T50/40/40 charging stations plus a 240v pump – all drawing around 17kva in total. This leaves at least 6kva or 25% capacity in reserve, (always best to run a gen set long term below 70% loading). We have a few customers running this one and all are happy with performance, with nothing but positive feedback. Just note the size and weight can be an issue depending on your trailer setup.
Leo – DFH Software Engineer
The 24kVA, 240V Single Phase Diesel Generator represents what the ABLE-designed generators offer - Reliability, Efficiency, Uncompromised Safety, and Incredible Value for Money!
The ABLE 24kVA diesel generator provides a consistent 24kVA power up to 25 hours continuous runtime at prime load and a mere 63dBA at 7 meters sound level. Mine site ready bunded and remote start capable, this generator is best suited for small businesses, homes, and farms backup power solutions.
Key Features:
Low RPM - 1500 RPM, 4 Cylinder Engine: Generators with a low RPM last longer and have a more stable operation.
Water Cooled: Handles Australia's north, no sweat
Diesel Fuelled: Very economical for low cost running and low consumption
Clean Mains-Type Power: Thanks to our 4 poles brushless alternator with AVR
Easy to use: Straight forward and reliable generator controller
| Prime Power : | 24kW / 24kVA 240 Volts 100Amps |
| Standby Power : | 24kW / 24kVA |
| Power Factor : | 1 |
| Phase Voltage : | Single Phase 240 Volt |
| Frequency : | 50 Hertz |
| Engine : | OEM 4 Cylinder Diesel Turbo Charged |
| RPM : | 1500/min |
| Cooling Method : | Water Cooled - Rated For Australia's North |
| Alternator : | Single Phase 4 Pole Brushless Synchronous -/c AVR |
| Starter System : | 12-volt Electric - Battery Included |
| Controller : | Comap MRS11 |
2 Wire / Remote Start Capable | |
Over Temperature Protection | |
Over Current Protection | |
Low Oil Protection | |
| Safety Systems : | Battery Isolator |
| Emergency Stop | |
| Failsafe Shutdown Fuel Solenoid | |
| Noise Level : | 63 dBA at 7 metres |
| Fuel Tank Capacity : | 165 Litres (-/c Fuel Gauge) |
| Running Time : | 25 Hours Continuous (prime load) |
| Fuel Consumption : | 6.5 litres/hour (prime load) |
| Chassis Enclosure : | Lockable |
| Sound Deadening Throughout | |
| Weather-Resistant Powder Coating | |
| Stainless Steel Fittings | |
| External Use | |
| Mine Site Ready Bunding : | Yes |
| ATS (Mains Failure) : | Easy Connect Plug (ATS Box Optional) |
| Single Phase Outlets : | 3 x 15 Amp IP66 |
| Three Phase Outlets : | No |
| Hardwire Terminals : | Yes |
| RCD / RCBO : | Australian Standard (IP67 Enclosed) |
| Options : | Automatic Start Systems |
GSM | |
Timer | |
Wireless Remote | |
Solar System Compatible (Majority) | |
ATS (Mains Failure Detection / Auto Transfer Switch) | |
| Minespec Padlockable Battery Isolator | |
| Weight : | 880 kg |
| Dimensions : | 187 L x 80 W x 122 H cm |